Securing Element.
A. Place new or cleaned element evenly on base plate. Be sure element
seats properly on base and there is no dirt or particulate present on
sealing surfaces.
B. Place top plate (if necessary) on element by centering on tap bolt.
C. Secure washer and wing nut to end cap (or top plate) and tap bolt.
Element must be tightly secured. Note: DO NOT over tighten!
*WARNING*
Defective installation may cause system or
pump contamination. Use only genuine
Solberg replacement parts.
MAINTENANCE RECOMMENDATIONS
1. Pressure drop readings are recommended to have an effective air filter.
Always document initial pressure drop during start-up when element is clean.
Replacement cartridge is needed when system experiences 10” to 15” / 250-
380mm H
2
O higher pressure drop above the initial reading. Refer to page 4
for instructions.
2. Always check replacement cartridge gaskets to insure they are adhered
uniformly along the end caps during handling. If not, contact Solberg
Manufacturing, Inc. immediately. Do not modify or change from Solberg
specified parts!
3. Always check inlets/outlets, element base and its components when replacing
element to insure cleanliness. Wipe clean if necessary.
4. Operate only when a proper seal exists.
Ph: 630.773.1363 Fax: 630.773.0727 Email: [email protected] Web: www.solbergmfg.com
Rev: MMEL-6294