Solberg Manufacturing, Inc., 1151 Ardmore Itasca, IL 60143 USA
Ph: 630.773.1363 Fax: 630.773.0727 Email: [email protected] Web:
Page 12
*WARNING*
Failure to seat the element properly may result
in contaminant by-pass resulting in damage to
equipment.
2. Check weather hood is installed correctly onto housing.
*WARNING*
If the air flow is reversed through a Solberg
filter unit, be sure to check the element and
housing internals for damage. Failure to do so
may result in damage to equipment.
3. Be sure all fasteners and hardware have been tightened.
Section D
MAINTENANCE RECOMMENDATIONS
1. Pressure drop readings are recommended to have an effective air filter.
Always document initial pressure drop during start-up when element is clean.
Replacement cartridge is needed when
system experiences 10” to 15” / 250-
380mm H
2
O above drop above the initial reading. Refer to page 4 for initial
values.
2. Always check inlets/outlets, element base and its components when replacing
element to insure cleanliness. Wipe clean if necessary.
3. Operate only when a proper seal exists.