TEMPERATURE LIMIT STOP SET UP
Santec Pressure Balanced Valve has a temperature limit stop ( please
see Illustration C) which once set properly can provide a safe and
comfortable hot water. Below is the limit stop installation procedure:
- Remove all Handle trim parts, including the trimplate.
- remove all internal parts up to the Limit Stop, do not remove the
Mechanical Stop.
If Mechanical Stop is removed please follow the instruction bellow
- Turn the cartridge clockwise until it is stopped. Do not force
to avoid damaging the cartridge.
- Insert the Mechanical Stop onto the catridge
- Turn the cartridge counterclockwise to open the water line. Turn
until it reaches the maximum hot water desired by the user.
- Place Limit Stop as shown in the Illustration D2.
- Reinstall all the parts accordingly to the Illustration C.
PM-280 - SERVICE VALVE (OPTIONAL)
VALVE CARTRIDGE - TE010
MECHANICAL STOP- TE013
LIMIT STOP- TE014
PM-010 - STEM
TEFLON WASHER
PM-009 - LOCK PLATE
PM-012 - LOCK NUT
PM-011 - ALL THREAD
Illustration C
FILTER SCREEN - TE012
DIVERTER CARTRIDGE- TE050
PM-460 - DIVERTER SLEEVE
DIVERTER KNOB-P0258
PRESSURE BALANCED TUB/SHOWER VALVE (PB-3950)
INSTALLATION AND ROUGH-IN
PLATE GROMMET- PM-465