TEMPERATURE LIMIT STOP SET UP

Santec Pressure Balanced Valve has a temperature limit stop ( please
see Illustration C) which once set properly can provide a safe and
comfortable hot water. Below is the limit stop installation procedure:

- Remove all Handle trim parts, including the trimplate.
- remove all internal parts up to the Limit Stop, do not remove the
Mechanical Stop.

If Mechanical Stop is removed please follow the instruction bellow
- Turn the cartridge clockwise until it is stopped. Do not force
to avoid damaging the cartridge.
- Insert the Mechanical Stop onto the catridge

- Turn the cartridge counterclockwise to open the water line. Turn
until it reaches the maximum hot water desired by the user.
- Place Limit Stop as shown in the Illustration D2.
- Reinstall all the parts accordingly to the Illustration C.