beautypg.com

Trim installation (1) – Santec 9529KT-TM User Manual

Page 6

background image

0 6

9527/9529KL, KR, KT _ _

Step 1- Take the plastic guard off the valve.

Step 2- Thread the bonnet nut, all thread and stem key onto the valve

and lightly tighten assembly with a 1” plumber’s socket wrench. See

Diagram A on next page.

Step 3- Make a mark on the all thread that is a maximum distance from

Step 4- Un-thread the bonnet nut, all thread and stem key from the

valve and remove the stem key only from the rest of the assembly.

Step 5- Using a hacksaw, cut the excess at the mark on the all thread.

Re-insert the stem key into the assembly. From the end of the newly cut

all thread measure a distance of 1/2” on the stem key and make a

mark. Cut the excess at the mark on the stem key. See Diagram B on

next page.

Step 6- Re-thread the bonnet nut, all thread and stem key back onto the

valve and snugly tighten assembly with a 1” plumber’s socket wrench.

See Diagram B .

Trim Installation (1)

H a n d l e T r i m

2-1/2” - 3”

Backset

Finished Wall

1-1/4“

Past

Finish

Wall

All Thread

Bonnet Nut

Stem Key

Finished Wall

1/2”

Stem Key Past

All Thread

D i a g r a m A

D i a g r a m B

Maximum

This manual is related to the following products: