Handle trim installation (4), Pop up drain installation (1), Handle trim pop up drain – Santec 6520VO User Manual
Page 4
Handle Trim Installation (4)
Remove drain flange and drain plug from pop-up assembly.
Pop Up Drain Installation (1)
D r a i n P l u g
D r a i n F l a n g e
Aerator
housing
Ball Rod Hole
Gasket
Washer
Lock nut
Drain flange
0 7
0 8
Inlet Hoses
Loop and connect the flexible hoses to the tee connector. Tighten to avoid leakage.
Connect and tighten the inlet hoses to the supply lines.
After the connections have been made, carefully remove the aerator housing by
unscrewing it counter-clockwise. Turn on the water supply at the valves beneath the sink
or counter and check for leakages at all joints. If water leaks from any of the connections,
tighten the connection until the leakage stops. If no leakage, slowly turn the handles to
the full open position and let the water flush for approximately 45 seconds. This can
prevent damages to the ceramic cartridges caused by debris in the supply lines. When
finished flushing out system, carefully screw the aerator housing back into the spout.
Apply a ring of silicone caulking to underside of drain flange. Do not use plumber’s putty
which can damage finish.
Insert threaded end of the assembly up from below sink.
Completely thread drain body into drain flange and align with ball rod hole facing back.
Then tighten lock nut from below. Clean excess silicone with paper towel.
HANDLE TRIM
POP UP DRAIN