Sandia Aerospace STX 165 Installation Manual User Manual
Page 10
Section 3 Installation Procedures
3.1
General
The STX 165 and STX 165R are supplied with two Sub-D mating connectors and a connector
clamps. The Sub-D connectors use screw lock assemblies to secure the connectors to the unit. In
some installations both connectors will not be needed. The spare connector can be discarded. Also
supplied is a SMA connector for use in connecting the antenna coax. It is important that proper
installation techniques be observed in attaching wires and building the antenna cable. The static port
connection must be securely attached to prevent any leakage. Failure to observe proper installation
techniques could result in a failure of a connection and cause intermittent or non operation of the
STX 165 or STX 165R.
The STX 165 and STX 165R must never be turned on without the antenna
connected. FAILURE TO DO SO COULD CAUSE DAMAGE TO THE TRANSMITTER.
3.2.2
STX 165R Remote Mount
3.2.2.1
Supplied
STX 165R P/N 305831-00
Installation Kit 305994-00
9 Pin Sub D Female Connector P/N 305214
Clamp, D Conn, Size 1 P/N 305207
15 Pin Sub D Female Connector P/N 305215
Clamp, D Conn, Size 2 P/N 305208
SMA Connector P/N 306109
3.2.2.2
Required but not supplied
3 or 4 each number 6-32 or 8-32 pan head screws for mounting unit.
RF antenna coax (RG 400U or equivalent)
Cables
3.2.2.3
Optional
Remote mounting tray, P/N 305835-20
3.2
Equipment Required
3.2.1
STX 165 Panel Mount
3.2.1.1
Supplied
STX 165 P/N 305832-00
Installation Kit 305994-00
9 Pin Sub D Connector P/N 305214
Clamp, D Conn, Size 1 P/N 305207
15 Pin Sub D Connector P/N 305215
Clamp, D Conn, Size 2 P/N 305208
SMA Connector P/N 306109
3.2.1.2
Required but not supplied
4 each 6-32 pan head screws for mounting to the instrument panel.
RF antenna coax (RG 400U or equivalent)
Cables
Static port tubing
3.2.1.3
Optional
STP 78 OAT Probe. Sandia P/N 305561-91
9
306100-00