Quick Charge SCOXU User Manual
Page 8

F5 is for Lithium ion batteries and must be pre-programmed at the
factory.
The adjustments are:
d0 standard gassing/absorption cycle. Applicable to most
applications
d1 shortened gassing/absorption cycle. For frequent shallow
discharging, or frequent recharging of batteries with very little
discharge. Suitable for opportunity charging.
d2 lengthened gassing/absorption cycle. For batteries requiring
long gassing/absorption cycles. US Battery, and Full River are
two brands that benefit from longer charge cycles.
r0 when set to the F2 profile, charge will terminate, and will not
monitor the battery.
r1 when set to the F2 profile, charge will terminate, and the battery
will be checked weekly, if the voltage falls to a predetermined
level, the charger will recycle and bring the battery(s) back up.
To change the profile: Be firm and deliberate when pressing the
button. Disconnect one charge lead. Plug the charger into AC
power. Press and hold the “Battery Voltage” button. The display
will flash the current setting. Press the button repeatedly, and stop
at the desired profile. The display will stop flashing and remember
the setting. Unplug AC power, and reconnect the battery. When
powered back up, the display will flash the changed setting, and
the charge cycle will begin.
To change the adjustments: Follow the above procedure, except
press the button twice to enter the
d
menu, press the button a third
time and hold to set the display flashing and to make a change. To
change the
r
setting, press the button three times to enter the
r
menu, then a forth time, and hold to set the display flashing and to