Unit won’t stay lit

Wind

Running out of fuel

PROBLEM

POTENTIAL CAUSE

ACTION REQUIRED

Burner will not light

Gas supply turned off

Out of propane

Blockage in the gas system

Misalignment of the gas valve to
the venturi tubes of the burner.

Improper attachment of the
propane hose and regulator

Control knob left open at startup

or
Turning gas on too quickly

Unit won’t heat up (LP)

Troubleshooting Guide

Page 24

Turn on fuel supply and retry.

Confirm the flow of gas by smell or by listening for the hiss
of gas being emitted. Allow gas to clear before attempting to
relight.

Weigh your propane cylinder. A standard 20 lb. cylinder
will weigh about 18 lb. when it is empty and 38 lb. when it
is 80 % full.
(WARNING : Never take a propane cylinder indoors for
any purpose.)

Confirm that the venturi tubes are not blocked by insects or
other debris. Use a special venturi brush to clean (Fig. 16).

Use a pin or needle to carefully probe the orifice in the gas
valve. Never enlarge the orifice (Fig. 18).

Look under the front control panel and reinsert the gas
injector into the venturi tube, if required (Fig. 22).

Tighten the regulator’s plastic collar onto the cylinder valve.
Hand-tighten only (Fig. 4).

Always shelter your Grill from strong winds.

Confirm the flow of gas by smell, or by listening for the hiss
of gas being emitted.

Weigh your propane cylinder. A standard 20 lb. cylinder will
weigh about 18 lb. when it is empty and 38 lb. when it is 80
% full. (WARNING : Never take a propane cylinder indoors
for any purpose.)

For safety, the regulator coupling on your barbecue is
equipped with a flow control mechanism. This device limits
gas flow in the event of a sudden change in the demand for
gas. This may be engaged inadvertently, if a burner control
knob should be left ON when you open the propane cylinder
valve. Rapidly opening the valve can also engage flow control.
To resolve the problem, close your cylinder valve. Confirm
that all burner control knobs are in the OFF position. Open
the cylinder valve slowly (about 1 to 2 turns) and wait 5
seconds. Finally, turn a single burner ON and try relighting it.