Troubleshooting guide, Service – Coleman 2300 Series User Manual
Page 9
Troubleshooting Guide
Symptom
Problem
Solution
Yellow battery Low Light
on during operation
Battery voltage low
Charge battery
Battery defective
Replace battery (refer to maintenance section for
instructions)
Burner will not light
Propane cylinder empty
Replace cylinder
Propane cylinder frosted
Replace cylinder and reuse after thawing
Electronic circuit defective
Send to Coleman Service Center
Low or no water flow
Battery lead disconnected
Remove battery cover & reinstall lead
(less than 1 gallon per
minute)
Pump is not positioned properly
Rotate pump so “THIS SIDE UP” is facing upward
Water container out of water
Fill water container
Pump screen clogged
Remove and clean screen
Hose bent or kinked
Straighten hose
Pump unplugged
Make sure the black wire is plugged into back of heater
Air bubble in hose
Drain hose completely
Water leak at pump to
container
Fitting cross-threaded
Remove pump and reconnect to water container
Hose turns white or
discolors inside
Calcium buildup
Clean heater (refer to page 6 for cleaning instructions)
Water leaking from
inside heater
Defective seal or break
Send to authorized Coleman Service Center
Service
• Repairs to gas passages, electrical circuitry and associated components should be done only by Coleman or an authorized
service person.
• Owner repair and service should be limited and performed only to the following:
• Cleaning
• Propane cylinder leak checks and cylinder replacement
• Battery replacement
• Pump & pump hose replacement
• Repair to doors: battery compartment door & battery charger compartment door.
• For Coleman authorized service, call 1-800-835-3278 – TDD 316-832-8707
.
9