How Softheat hydronic baseboards work:
Inside a Softheat baseboard, a hermetically sealed water and
anti-freeze solution is heated by an electric heating ele-
ment. As the solution is heated, warmth is generated and
transmitted through dozens of aluminum fins along the
heater tube (it could initially take 30 to 60 minutes to warm a
room, depending on the room size). As the warmth spreads
outward from the heater, cooler air from the floor and wall nat-
urally flow toward the base of the heater. "Convection air heat-
ing" (See Figure 3) provides heat without fans, preventing the
heater from blowing or burning dust particles. The room is
warmed with even, comfortable heat without cold and hot
spots throughout the room. While Softheat offers everyone
a comfortably warm room, it was specifically designed to
reduce the effects of indoor allergens, compared to other
heating systems. Additional benefits include lower operat-
ing surface temperature and whisper quiet operation.

WARNING!

Element filled with
heat transfer fluid
containing 20%
Ethylene Glycol. In
the unlikely event of
leakage, if consumed,
call your local
poison control cen-
ter or seek medical
attention
immediately.

WARNING!

Risk of Fire. Heaters
must be kept clean
of lint, dirt and
debris.

Failure to follow
warnings may cause
heater to eject
sparks, ignite
materials, or cause
electrical shock.

Cold Air

Cold Air

Warm Air

Warm Air

Warm Air

Room Air

HEAT

LIMIT CONTROL

HEATING ELEMENTS

RED

RED

BLACK

RED

POLARIZED

BLADE PLUG

CLOSE L1

THERMOSTAT

WATTAGE SWITCH

RED

ON

HEAT

LIMIT CONTROL

BLACK

WHITE

POLARIZED

BLADE PLUG

CLOSE L2

THERMOSTAT

OFF L1

WATTAGE SWITCH

HEATING ELEMENTS

Single Pole Thermostat
EPA750 and EPA1000 (120 Volt)

EPA1500/3 (120 Volt)

Model

EPA750

EPA1000

EPA1500/3

BTUs

2560

3413

1707/3413/5120

Watts

750

1000

500/1000/1500

Volts (AC)

120

120

120

Phase

1

1

1

Hertz

60

60

60

Amps

6.3

8.3

4.2/8.3/12.5

Length*

47”

59”

71”

* Approximate Metric equivalents: 4' = 1,2m, 5' = 1,5m, 6' = 2m.

Operation Instructions

Figure 3.

HEATER MAINTENANCE

SOFTHEAT has no moving parts to wear
out, so it is virtually maintenance-free.
However, it is recommended to periodi-
cally remove the front cover (UNPLUG
UNIT FIRST)
and vacuum the lint or
dust from the inside of the heater to
maintain peak heat transfer into the air.
Use caution when vacuuming to avoid
damaging the aluminum fins.

PILOT LIGHT

THERMOSTAT

LIMIT

HEATER TUBE

RED

RED

RED

BLACK

BLACK

RED

HEATER ELEMENT

POLARIZED
BLADE
PLUG

Double Pole Thermostat
EPA750 and EPA1000 (120 Volt)

Please note: If your heater has a thermostat control knob that is labeled with an “OFF” position, the unit
is equipped with a double pole thermostat. No heating will occur when the thermostat is rotated to the
full counterclockwise “OFF” position.