O.S. Engines 25XZ User Manual
Page 17
32
Symptom
Cause
Corrective action
Symptom
Cause
Corrective action
Unstable idle
Unsuitable glowplug
Use suggested glowplug in the instructions.
Unsuitable fuel
Do not use extremely high nitro or low oil content fuel.
Extremely light flywheel
Add heavier flywheel.
Silencer is disconnected or is loose
Install silencer securely.
Not reaching expected peak r.p.m.
Insufficient warming up or running-in.
Set the needle only after warming up.
Complete running-in.
Silencer or manifold is not securely connected
or disconnected.
Replace seal ring.
Check the connections and secure them.
Fuel tubing from tank is split or broken.
Replace the tubing.
33
Symptom
Cause
Corrective action
Symptom
Cause
Corrective action
Poor response
Deteriorated glowplug
Replace glowplug.
Incorrect carburetor settings
Readjust low r.p.m. range with metering
needle and mixture control valve.
Incorrect setting of transmitter Exponential function. Check the transmitter setting.
Poor r.p.m. drop
Throttle position open too far.
Close metering needle to adequate position
to lower idle r.p.m.
Carburetor not fully seated
Install carburetor securely.
Incorrect linkage
Make sure the throttle servo linkage does not
bind and is connected correctly.
Metering needle closed too far.
Open the metering meedle a little.