5.4 Sprayer Manual Boom Height Switches

When a manual switch is pressed, an arrow will be displayed on the screen showing which
function is being activated. For example, if the left up switch is pressed then an up arrow will

be shown above the left boom.

Tilt (Variable Geometry) Switches:
While in Automatic Mode if either left or right boom tilt switches are pressed, the
corresponding boom section will go into Manual Mode. To return all boom sections to
Automatic Mode, press the Auto button.
If the Double Tap Wings function is enabled, the tilt down switches can be used to resume
Automatic Mode provided that at least one boom section is already in Automatic Mode.

Main Lift Switch:
While in Automatic Mode if the main lift up or down switch is momentarily pressed, the Target
Height is incrementally adjusted up or down. If the Double Tap Main option is enabled, this
feature is disabled.
Pressing and holding the main lift switch will always put the system into Manual Mode.
If the Double Tap Main function is enabled, the main lift down switch can be used to resume
Automatic Mode provided that at least one boom section is already in Automatic Mode..

* Some sprayer types may not have all the functionality listed above.