3 setting control options – NORAC UC5-BC-VT User Manual
Page 12
9
Figure 3: NORAC UC5™ Run Screen – Manual
Mode
Figure 4: NORAC UC5™ Run Screen –
Automatic Mode
In manual mode, the height displayed under each boom section is measured from the spray
nozzles to the soil (Soil Mode) or crop canopy (Crop Mode or Hybrid Mode). If there are five
height sensors on the sprayer, the height displayed is the average for each boom section. The
crop at the bottom of the screen indicates the mode the controller is in. If the green line is
above the crop, the system is in Crop Mode or Hybrid Mode. If the green line is below the
crop, the system is in Soil Mode.
5.3 Setting Control Options
To change these settings, click the Settings button to display the boom height control options
screen as shown in Figure 5.
Figure 5: Height Control Settings
Sensitivity:
The Sensitivity can be adjusted from 1 to 10, with 5 being the default setting. A lower number
will reduce the system sensitivity. Higher settings will speed up the response and also create a
greater demand on the hydraulics.
AUTO
Button
Boom Height
and State
MANUAL
Button
Settings
Button