4 roll sensor installation – NORAC 5468BC User Manual
Page 7
4
4 Roll Sensor Installation
1. Determine the location where the Reference Frame roll sensor will be mounted. It must
be mounted on the sprayer chassis on a non-moving part.
2. Securely mount the roll sensor to the included roll sensor bracket using the #6 machine
screws.
3. The orientation of the mounted roll sensor to the roll sensor bracket will depend on the
bracket mounting. The roll sensor CAN-bus connector must be pointing towards the
right side of the sprayer (when looking from the rear of the sprayer).
4. Mount the roll sensor and bracket to the non-moving frame member with the cable
towards the right.
The system will not function properly unless the cable on the roll sensor is facing
the right hand wing.
The roll sensors must be installed in the following order:
The lowest serial number on the boom frame.
The highest serial number on the reference frame.
Figure 1: Reference Frame Roll Sensor Mounting
If the previously installed roll sensors are part number 43740, they
must be replaced with version two roll sensors part number 43741.