19

6 Electrical Installation

1. Locate the valve module installed on the NORAC valve block. Remove the plugs installed

in positions 7 and 8.

2. Connect the 2 pin connector on cables C10 into positions 7 and 8 on the valve module.

Connect the other end of cables C10 to the 2 pin connectors on the NORAC expansion
block (V70).

3. If installing this kit on a sprayer that has an existing passive roll control system, disconnect

and remove the two NORAC roll sensors (small rectangular box with a cable running from
it). See for Figure 20 locations.

Figure 20: Roll Sensor Locations (Viewed from the rear of sprayer)

4. Connect the position sensor (E06) and the active roll cylinder (H75) to the 8-way coupler

(E11) using cable C04 and a 2-way coupler (E12).

Figure 21: Valve Module Connections

Output Number

Normal Function

1

Left Up

2

Left Down

3

Right Up

4

Right Down

5

Option 1

6

Option 2

7

Roll CW

8

Roll CCW