5 Hydraulic Installation
Ensure all pressure has been bled from the system before disconnecting any lines
or fittings. Hydraulic pressure will exist on the wing tilt circuits unless the wings
are being supported by other means. The hydraulic installation may be performed
with the wings in transport position, resting on the ground or with the tilt cylinders
fully extended.
Component failure due to oil contamination is not covered under the NORAC UC5
system warranty. It is recommended that a qualified technician perform the
hydraulic installation.
5.1 Valve Assembly
1. On a clean surface remove all plastic plugs from the block.
2. Install the .047 orifice (F07A) into the “B” port of the expansion block with the notch facing
in. Install the 6MB-4MOR (F12) fitting into the “B” port. Tighten to 18 ft-lbs (24 Nm).
3. Install the .042 orifice (F07B) into the “A” port of the expansion block with the notch facing
in. Install the 6MB-4MOR (F12) fitting into the “A” port. Tighten to 18 ft-lbs (24 Nm).