Appendix A: Alternate Configuration

If your sprayer has European style slant control, you will need to reconfigure the switch box as
shown below. This is only required for sprayer types which are driving the slant output from
the Input Module. Reconfigure the pins on cable C26 and C20 as follows:

Connector

Pin Location

Connector

Pin Location

Power

White

OEM 3 (C26)

1

OEM 3 (C26)

1

Ground

Black

OEM 3 (C26)

12

OEM 3 (C26)

12

Remote Auto

Brown

OEM 3 (C26)

11

OEM 3 (C26)

11

Remote Manual

Blue

OEM 3 (C26)

10

Thru 2 (C20)

4

Main Up

Purple

OEM 3 (C26)

9

OEM 3 (C26)

9

Main Down

Yellow

OEM 3 (C26)

8

OEM 3 (C26)

8

Roll CW

Red

Thru 2 (C20)

3

OEM 3 (C26)

6

Roll CCW

Orange

Thru 2 (C20)

4

OEM 3 (C26)

10

European Style Slant Configuration

Wire Color

Function

(Cable C26)