6 Electrical Installation

1. Locate the valve module installed on the NORAC valve block.

2. Remove the plugs installed in positions 5 and 6.

3. Connect the 2 pin connector on cables C10 into positions 5 and 6 on the valve module.

4. Connect the other end of cables C10 to the 2 pin connectors on the NORAC expansion

block (V01).

5. Remove the existing cable C03 from the existing input module. Connect the unplugged

connector from existing cable C03 into the 3-way coupler (E10).

6. Connect one end of cable C03 to the existing input module and the other end to the 3-way

coupler (E10).

7. Connect one end of cable C04 to the 2-way coupler (E12) and the other end to the 3-way

coupler (E10).

8. Connect the cable from the Roll Sensor (E04) to the other end of the 2-way coupler (E12).












Figure 7: Valve Module Connections

Output Number Normal Function

1

Left Up

2

Left Down

3

Right Up

4

Right Down

5

Main Up

6

Main Down

7

Option 3

8

Option 4