7.2 Roll Sensor Mounting Guidelines: Trapeze-Suspended Booms

1. When mounting the roll sensors, mount one to the trapeze link (boom frame – lowest

serial number), one to boom carrier frame (intermediate frame) and one to the chassis

(reference frame – highest serial number). For optimal performance, minimize the distance
from the boom frame roll sensor to the pivot point (A) and minimize the vertical distance
between the intermediate frame roll sensor and the pivot point (B).

Figure 11: Roll Sensor Mounting on a Trapeze Suspended Boom

2. Ensure the roll sensors are relatively level when the sprayer boom and chassis are level.

3. Ensure that the Reference Frame (chassis) roll sensor has the highest serial number and the

Boom Frame roll sensor has the lowest serial number.

4. All roll sensor cables should be pointing towards the right hand wing of the sprayer.

5. Ensure roll sensors are mounted adequately and that the cables provide enough slack to

allow sufficient boom roll.