10 hydraulic installation, 1 valve assembly – NORAC UC5-BC-SC01 User Manual
Page 24
20
10 Hydraulic Installation
Ensure all pressure has been bled from the system before disconnecting any lines
or fittings. Hydraulic pressure will exist on the wing tilt circuits unless the wings
are being supported by other means. The hydraulic installation may be performed
with the wings in transport position, resting on the ground or with the tilt cylinders
fully extended.
Component failure due to oil contamination is not covered under the NORAC UC5
system warranty. It is recommended that a qualified technician perform the
hydraulic installation.
10.1 Valve Assembly
1. On a clean surface remove the plastic plugs from the block.
2. Install the 6MJT 6MBR tee fittings (F02) on the "P" and "T" ports and tighten to 18 ft-lbs.
3. Install orifices F06 into the "B" ports with the notch facing outward.
4. Install the orifices F06 into the "A" ports with the notch facing inward.
5. Install the 6MB-6MJ fittings (F07) into the “A” and "B" ports and tighten to 18 ft-lbs.
6. Install the 6MJ 6FJX90 fittings (F03) onto the 6MB-6MJ fittings (F07) in the “A” and “B”
ports.
Figure 23: NORAC Valve Block Details