beautypg.com

9 connecting the sensors to the canbus – NORAC UC5-BC-RG10 User Manual

Page 23

background image



20

9 Connecting the Sensors to the CANbus

1. Fasten the 8-way coupler to the boom with cable ties.

2. Connect one roll sensor to the 8-way coupler using cable C03 and a 2-way coupler (E12).

Connect the other roll sensor directly to the 8-way coupler.

3. Connect the main lift sensor to the 8-way coupler using cable C04 and a 2-way coupler

(E12). Cable C04 and item E12 may not be needed if the 8-way coupler is mounted close
enough to the main lift sensor.

4. Connect two cables (C05) to the 8-way coupler and route along the booms to the wing

sensors. Follow existing cables and hoses to be sure the cable will not be pinched or
stretched.

Figure 20: UC5 Module Locations and Cable Connections

5. At the sensor brackets, attach a 2-way coupler with terminator (E20) to the sprayer boom.

The 2-way coupler with terminator is the white two way coupler. Plug the sensor and the
CANbus cable into the 2-way coupler.

NOTE: Some earlier booms will require a power jumper (NORAC P/N: 43250-10)

to be inserted into the 8-way coupler in order to function.

Ensure that all unused connectors are plugged with the plugs provided.