beautypg.com

5 main lift sensor installation – NORAC UC5-BC-RG10 User Manual

Page 16

background image



13

6.5 Main Lift Sensor Installation

1. There are a variety of ways to mount the main lift bracket on most sprayers. The bracket

should position the sensor approximately in the center of the sprayer, forward of the

boom. An example of this mounting is illustrated in Figure 10.

2. Mount the ultrasonic sensor to the main lift bracket.

Figure 10: Example Mounting of the Main Lift Bracket

Avoid mounting the main lift sensor over or near a wheel-track. Measurements

from the wheel-track do not provide an accurate crop height and will cause
measurement and control error.

Ensure the bracket does not collide with any other part of the sprayer throughout
the full range of main lift motion.