19
8
Module Installation
An optional module mounting bracket kit is available for purchase from NORAC. The
mounting brackets are compatible with control modules and input modules. One kit is needed
per module.
Item
Part Number
Name
Quantity
B20
43708
UC5 MOUNTING BRACKET KIT (CONTROL AND INPUT MODULES)
1
8.1 Control Module
1. Refer to Figure 2 and Figure 18.
2. There are two power cables included. Power cable C30 (43250-07) is used for 4000 series
sprayers. Power cable C31 (43250-04) is used for 5000 series sprayers. Follow the
appropriate installation instructions for the sprayer series.
8.1.1 4000 Series Installation
1. Connect the power cable (C30) to one of the two CANbus connectors on the control
module. Connect the other end of the power cable to an appropriate power source.
2. Route cable C01 from the other CANbus connector out of the cab and connect to a three
way coupler (E10). Use bracket B12 to route cable C01 out of the sprayer cab.
8.1.2 5000 Series Installation
1. Connect the power cable (C31) to one of the two CANbus connectors on the control
module. Connect the other end of the power cable to an appropriate power source.
2. Route cable C01 from the other CANbus connector out of the cab and connect to a three
way coupler (E10). Route cable C01 out of the cab through the rear right side cab access
hatch.
8.1.3 Both Installations
1. Securely mount the control module (E01) inside the sprayer cab using screws, cable ties or
optional brackets.
2. Connect the display terminal to the control module using the display cable. This display
cable must be connected to the end of the control module with only one Deutsch
connector.
3. Secure the three way coupler to the sprayer chassis. Connect cable C02 to a free
connector on the three way coupler (E10) and route the cable towards the boom.