9 Connecting the Sensors to the CANbus
1. Fasten the 8-way coupler to the boom with cable ties. Route cable C02 from the valve
module to the 8-way coupler (E11).
2. Connect the boom frame and intermediate frame roll sensors to the 8-way coupler.
3. Connect the reference frame roll sensor to the 8-way coupler using cable C03 and a 2-way
coupler (E12).
4. Connect the main lift sensor to the 8-way coupler using cable C02 and a 2-way coupler
(E12). Cable C02 and item E12 may not be needed if the 8-way coupler is mounted close
enough to the main lift sensor.
5. Connect two cables (C05) to the 8-way coupler and route along the booms to the wing
sensors. Follow existing cables and hoses to be sure the cable will not be pinched or
stretched.
Figure 22: CANbus Connections
6. At the sensor brackets, attach a 2-way coupler with terminator (E20) to the sprayer boom.
The 2-way coupler with terminator is the white two way coupler. Plug the sensor and the
CANbus cable into the 2-way coupler.
7. Insert the 6-pin plugs (P03) into the remaining connectors on the 8-way coupler.
Ensure that all unused connectors are plugged with the plugs provided.