NORAC UC5-BC-MC01 User Manual
Page 19
16
7.2 Roll Sensor Mounting Guidelines: Trapeze-Suspended Booms
1. When mounting the roll sensors, mount one to the boom frame – lowest serial number,
one to boom carrier frame (intermediate frame - non-pivoting portion of the sprayer) and
one to the chassis (reference frame) – highest serial number. For optimal performance,
minimize the distance from the boom frame roll sensor to the pivot point (A) and minimize
the vertical distance between the intermediate frame roll sensor and the pivot point (B).
Figure 13: Roll Sensor Mounting on a Trapeze Suspended Boom
2. Ensure the roll sensors are relatively level when the sprayer boom and chassis are level.
3. The reference frame (chassis) roll sensor will be the roll sensor with the highest serial
number. It should be mounted on the chassis of the sprayer (Figure 15).
4. All roll sensor cables should be pointing towards the right hand wing of the sprayer.
5. Ensure all roll sensors are mounted adequately and that the cables provide enough slack to
allow sufficient boom roll.
Connectors towards
Right-hand Wing