beautypg.com

9 hydraulic installation, 1 expansion block assembly – NORAC UC5-BC-JD10A User Manual

Page 27

background image



24

9 Hydraulic Installation

Ensure all pressure has been bled from the system before disconnecting any lines
or fittings. Hydraulic pressure will exist on the wing tilt circuits unless the wings
are being supported by other means. You may wish to perform the hydraulic
installation with the wings in transport position, resting on the ground or with the
tilt cylinders fully extended.

Component failure due to oil contamination is not covered under the NORAC UC5
system warranty. It is recommended that a qualified technician perform the
hydraulic installation.

9.1 Expansion Block Assembly

1. Remove the four 4MBP plugs from the 3 station valve block (Figure 24).

2. Coat the four o-rings in hydraulic oil and install them into the expansion block. Ensure the

o-rings are seated properly.

3. Attach the expansion block to the 3 station block using the included spring washers and

bolts.

4. Tighten the bolts to 31 ft-lbs.