3 Installation

1. Install the UC4.5 Control Panel (E01) in the cab of the sprayer. Mount the panel where it

will be clearly visible and within easy reach of the operator.
A good spot to mount the UC4.5 control panel is on the right hand side of the cab to the
Roll Over Protection Bar. Four pilot holes for the screws provided need to be drilled to
facilitate the control panel mounting.
Another option is to purchase an adapter for the flexible panel mount that has a 3/8" NC
threaded stud on the end to bolt through an existing mount. These can be found at your
local outdoor store as a RAM mount part number RAM-B-236. (See

http://www.ram-

mount.com/

)

Figure 1: Cable Configurations: C10, C11 and C30

2. Connect C10 to the UC4.5 Control Panel in the sprayer cab. Ensure that both connectors

(P16 and P4) are connected to the panel. Cable tie C10 to the RAM mount to help provide
strain relief.

3. Route the plug end (P12/P6) of C10 to the exterior of the cab and connect to C11 at the

hitch. Ensure cable is routed in a safe manner to avoid damage.

4. Connect C30 to P6A on C10 using E12. Connect C30 to an appropriate power supply.

5. All other cables and connections are factory installed.