9 completing the factory installation – NORAC UC4.5-BC-FT1 User Manual
Page 22
19
9 Completing the Factory Installation
1. Test the functionality of the original manufacturer’s boom controls. The NORAC Control
Panel (E01) does not need to be powered up for the original switches to function. Unfold
the booms and raise/lower each boom and main section.
Confirm that the cabling and hoses are agreeable to the entire range of motion.
2. If any functions do not work, review the hydraulic and electrical portions of this manual to
check for proper installation.
3. Unfold the booms and level to 90 cm (or 35 inch) nozzle height. At this point ensure the
sensors are reading from an adequate and uniform target, such as gravel or dirt, or
concrete.
4. By using the “Quick Install” feature of the UC4.5 panel, the system may be configured in
preparation for the End-User. However, a hydraulic “ReTune” procedure will be required
for optimal performance. This is required to tune the UC4.5 hydraulic parameters to those
of the End-User tractor hydraulic system.
5. To perform the “Quick Install” procedure, select the FT1 sprayer type. Press and hold the
switch (for several seconds) until the word “SENSOR” appears on the UC4.5 control
panel screen.
6. The UC4.5 control panel will then prompt the installer to “EXIT CAB AND PUSH BOOM
TIP DOWN TO GROUND”. When exiting the cab and approaching the boom, avoid
walking near the sensors as this may result in measurement error.
7. At this point the UC4.5 panel should display the Main Operating Screen:
M 90 M
(example)
8. This indicates the system is ready for the second stage of installation. This will be carried by
the end user (for the reasons as described previously in Step 4).