beautypg.com

Milwaukee Tool 2266-20NST User Manual

Page 3

background image

4

5

At 5' away, spot is 5" in diameter

At 3' away, spot is 3" in diameter

At 1' away, spot is 1½" in diameter

WARNING

Never connect the Tem-

perature Probe to an energized circuit.

ACCESSORIES

For a complete listing of accessories refer to your
MILWAUKEE

Electric Tool catalog or go online to

www.milwaukeetool.com. To obtain a catalog, con-
tact your local distributor or a service center.

WARNING

Always remove batteries

before changing or removing accessories.
Only use accessories specifi cally recommend-
ed for this tool. Others may be hazardous.

MAINTENANCE

WARNING

To reduce the risk of per-

sonal injury and damage, never immerse
your tool in liquid or allow a liquid to fl ow
inside it.

WARNING

To reduce the risk of injury,

always remove the batteries from the tool
before performing any maintenance. Never
disassemble the tool. Contact a MILWAUKEE

service facility for ALL repairs.

Cleaning

Clean dust and debris from tool. Keep tool handles

clean, dry and free of oil or grease. Use only mild

soap and a damp cloth to clean the tool since certain

cleaning agents and solvents are harmful to plastics

and other insulated parts. Some of these include

gasoline, turpentine, lacquer thinner, paint thinner,

chlorinated cleaning solvents, ammonia and house-

hold detergents containing ammonia. Never use

fl ammable or combustible solvents around tools.

Repairs

For repairs, return the tool to the nearest service

center listed on the back cover of this operator's
manual.

Maintaining Tool

Keep your tool in good repair by adopting a regular

maintenance program. After six months to one year,

depending on use, return the tool to a MILWAUKEE

service facility for repairs.

If the tool does not start or operate at full power

with fully charged batteries, clean the contacts

on the battery door. If the tool still does not work

properly, return the tool to a MILWAUKEE service

facility for repairs.

Cleaning the Laser Windows

Clean the laser windows with a soft, moist cloth to

keep them clean and clear. Remove battery pack

before cleaning.

Contact Temperature Measurement with K-Type
Probe

Only use K-type Temperature Probes with this

meter.

1.Insert the probe. The unit detects a connection of

a K-type probe and displays the contact tempera-

ture (KTC) as the secondary measurement.

2 The display will continue to update

the contact temperature (KTC)

while the temperature probe reach-

es thermal equilibrium with the

object being measured. The display

will shut off after about 20 min.

3.To return to IR mode, remove the K-type probe.

Temperature Alarm

Press the Alarm button to turn on the alarm func-

tion. If the temperature reading is outside the preset

range, the temperature reading and bell icon will

fl ash and an alarm will sound.

Muting Alarm

Mute the alarm by pressing the

Alarm button. The bell icon will go

off. The temperature reading will

continue to fl ash as long as it is

outside the preset range.

Setting Preset Range for the
Alarm

1. To set the alarm range, pull and

hold the trigger and then press

the Alarm button. Repeat to toggle

between LO and HI settings.

2. Pull the trigger to increase the

values, press the Alarm button

to decrease the values. Wait 3

seconds for the ranges to save

and exit.

Low Battery

When the Low Battery icon is dis-
played, change the batteries.

MILWAUKEE

Test & Measurement Products (including bare

tool, li-ion battery pack(s) and battery charger but excluding
alkaline batteries) are warranted to the original purchaser
only to be free from defects in material and workmanship.
Subject to certain exceptions, MILWAUKEE will repair or
replace any part on this product which, after examination,
is determined by MILWAUKEE to be defective in material or
workmanship for a period of fi ve (5) years* after the date of
purchase. Return the Test & Measurement tool and a copy
of proof of purchase to the nearest Milwaukee Electric Tool
Corporation - factory Service Center. This warranty does not
apply to damage that MILWAUKEE determines to be from re-
pairs made or attempted by anyone other than MILWAUKEE
authorized personnel, misuse, alterations, abuse, normal
wear and tear, lack of maintenance, or accidents.
*The warranty period for the LITHIUM-ION battery pack
that ships with the Test & Measurement tool is two (2)
years from the date of purchase. *Alkaline battery that
ships with Test & Measurement tool is separately war-
ranted by the battery manufacturer. *The warranty period
for a NON-CONTACT VOLTAGE DETECTOR – 2201 20
is one (1) year from the date of purchase.
Warranty Registration is not necessary to obtain the
applicable warranty on MILWAUKEE product. The manu-
facturing date of the product will be used to determine the
warranty period if no proof of purchase is provided at the
time warranty service is requested.

ACCEPTANCE OF THE EXCLUSIVE REPAIR AND REPLACEMENT

REMEDIES DESCRIBED HEREIN IS A CONDITION OF THE CON-

TRACT FOR THE PURCHASE OF EVERY MILWAUKEE PRODUCT. IF

YOU DO NOT AGREE TO THIS CONDITION, YOU SHOULD NOT PUR-

CHASE THE PRODUCT. IN NO EVENT SHALL MILWAUKEE BE LIABLE

FOR ANY INCIDENTAL, SPECIAL, CONSEQUENTIAL OR PUNITIVE

DAMAGES, OR FOR ANY COSTS, ATTORNEY FEES, EXPENSES,

LOSSES OR DELAYS ALLEGED TO BE AS A CONSEQUENCE OF

ANY DAMAGE TO, FAILURE OF, OR DEFECT IN ANY PRODUCT

INCLUDING, BUT NOT LIMITED TO, ANY CLAIMS FOR LOSS OF

PROFITS. SOME STATES DO NOT ALLOW THE EXCLUSION OR

LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES,

SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO

YOU. THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER

EXPRESS WARRANTIES, WRITTEN OR ORAL. TO THE EXTENT

PERMITTED BY LAW, MILWAUKEE DISCLAIMS ANY IMPLIED WAR-

RANTIES, INCLUDING WITHOUT LIMITATION ANY IMPLIED WAR-

RANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR

USE OR PURPOSE; TO THE EXTENT SUCH DISCLAIMER IS NOT

PERMITTED BY LAW, SUCH IMPLIED WARRANTIES ARE LIMITED

TO THE DURATION OF THE APPLICABLE EXPRESS WARRANTY AS

DESCRIBED ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS

ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE

LIMITATION MAY NOT APPLY TO YOU, THIS WARRANTY GIVES

YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER

RIGHTS WHICH VARY FROM STATE TO STATE.

This warranty applies to product sold in the U.S.A. and Canada only.

TECHTRONIC INDUSTRIES' warranty is for 5 year since the original

purchase date.

This warranty card covers any defect in material and workmanship

on this Power Tool.

To make this warranty valid, present this warranty card, sealed/

stamped by the distributor or store where you purchased the product,

to the Authorized Service Center (ASC). Or, if this card has not been

sealed/stamped, present the original proof of purchase to the ASC.

Call toll-free 1 800 832 1949 to fi nd the nearest ASC, for service, parts,

accessories or components.

Procedure to make this warranty valid

Take the product to the ASC, along with the warranty card sealed/

stamped by the distributor or store where you purchased the product,

and there any faulty piece or component will be replaced without

cost for you. We will cover all freight costs relative with this warranty

process.

Exceptions

This warranty is not valid in the following situations:

a) When the product is used in a different manners from the end-user

guide or instruction manual.

b) When the conditions of use are not normal.

c) When the product was modifi ed or repaired by people not autho-

rized by TECHTRONIC INDUSTRIES.

Note: If cord set is damaged, it should be replaced by an Authorized

Service Center to avoid electric risks.

SERVICE AND ATTENTION CENTER

Rafael Buelna No.1.

Col. Tezozomoc Mexico, Azcapotzalco D.F.

Ph. 01 800 832 1949

IMPORTED AND COMMERCIALIZED BY:

TECHTRONIC INDUSTRIES MEXICO, .S.A. DE C.V.

Av. Santa Fe 481 piso 6, Col. Curz Manca.

CP 05349, Cuajimalpa, D.F.

LIMITED WARRANTY - MEXICO,

CENTRAL AMERICA AND CARIBBEAN

Model:

Date of Purchase:

Distributor or Store Stamp:

LIMITED WARRANTY -

USA AND CANADA

Distance to Spot 12:1

—— Center of Spot
– – – Laser pointer (approx. 3/4" above center of spot)
Spot size at distance indicated

This manual is related to the following products: