Milwaukee 2282-20

18

EN

Technical Data

* applies for 100 % target reflectivity (white painted
wall), low background illumination, 25 ºC
** applies for 10 to 500 % target reflectivity, high back-
ground illumination, - 10 ºC to + 50 ºC
*** Tolerances apply from 0.05 m to 10 m with a confi-
dence level of 95%. The maximum tolerance may
deteriorate to 0.1 mm/m between 10 m to 30 m and to
0.2 mm/m for distances above 30 m
**** applies for 100 % target reflectivity, background
illumination of approximately 30'000 lux
***** after user calibration. Additional angle related
deviation of +/- 0.01° per degree up to +/-45° in each
quadrant. Applies at room temperature. For the whole
operating temperature range the maximum deviation
increases by +/- 0.1°.

For accurate indirect results, the use
of a tripod is recommended. For
accurate tilt measurements a trans-
verse tilt should be avoided.

Message Codes

If the message Error does not disappear
after switching on the device repeatedly,
contact the dealer.
If the message InFo appears with a
number, press the Clear button and
observe the following instructions:

Distance measurement

Typical Measuring Tolerance* ± 1.5 mm / 0.06 in ***

Maximum Measuring
Tolerance**

± 2.5 mm / 0.10 in ***

Range of target plate

80 m / 262 ft

Typical Range*

80 m / 262 ft

Range at unfavourable
condition ****

60 m / 197 ft

Smallest unit displayed

0.1 mm / 1/32 in

Ø laser point
at distances

6 / 30 / 50 mm
(10 / 50 / 80 m)

Tilt measurement

Measuring tolerance to laser
beam*****

± 0.2°

Measuring tolerance to
housing*****

± 0.2°

Range

360°

General

Laser class

2

Laser type

635 nm, < 1 mW

Protection class

IP54 (dust- and splash
water protected)

Autom. laser switch off

after 90 s

Autom. power switch-off

after 180 s

Battery durability (2 x AAA)

up to 5000 measure-
ments

Dimension (H x D x W)

117 x 57 x 32 mm
4.6 x 2.4 x 1.3 in

Weight (with batteries)

0.14 kg / 4.938 oz

Temperature range:
- Storage

- Operation

-25 to 70 °C
-13 to 158 °F
-10 to 50 °C
14 to 122 °F

Functions

Distance measuring

yes

Min/Max measuring

yes

Permanent measuring

yes

Stake-out

yes

Addition/Subtraction

yes

Area

yes

Volume

yes

Pythagoras

2-point, 3-point,
partial height

Smart Horizontal Mode /
Indirect height

yes

Height tracking

yes

Memory

20 displays

Beep

yes

Illuminated display

yes

Multifunctional endpiece

yes

i

No.

Cause

Correction

156

Transverse tilt
greater than 10°

Hold the instrument
without any transverse
tilt.

162

Calibration mistake

Make sure, the device
is placed on a abso-
lutely horizontal and flat
surface. Repeat the
calibration procedure. If
the mistake still occurs,
contact your dealer.

204

Calculation error

Perform measurement
again.

252

Temperature too
high

Let device cool down.

253

Temperature too
low

Warm device up.

255

Received signal too
weak, measuring
time too long

Change target surface
(e.g. white paper).

256

Received signal too
high

Change target surface
(e.g. white paper).

257

Too much back-
ground light

Shadow target area.

258

Measurement
outside of meas-
uring range

Correct range.

260

Laser beam inter-
rupted

Repeat measurement.