Milwaukee 2281-20

14

EN

Technical Data

* applies for 100 % target reflectivity (white painted
wall), low background illumination, 25 ºC
** applies for 10 to 500 % target reflectivity, high back-
ground illumination, - 10 ºC to + 50 ºC
*** Tolerances apply from 0.05 m to 10 m with a confi-
dence level of 95%. The maximum tolerance may
deteriorate to 0.1 mm/m between 10 m to 30 m and to
0.2 mm/m for distances above 30 m
**** applies for 100 % target reflectivity, background
illumination of approximately 30'000 lux

Message Codes

If the message Error does not disappear
after switching on the device repeatedly,
contact the dealer.
If the message InFo appears with a
number, press the Clear button and
observe the following instructions:

Care

• Clean the device with a damp, soft cloth.
• Never immerse the device in water.
• Never use aggressive cleaning agents

or solvents.

Distance measurement

Typical Measuring Tolerance* ± 1.5 mm / 0.06 in ***

Maximum Measuring
Tolerance**

± 2.5 mm / 0.10 in ***

Range of target plate

60 m / 197 ft

Typical Range*

60 m / 197 ft

Range at unfavourable
condition ****

50 m / 164 ft

Smallest unit displayed

0.1 mm / 1/32 in

Ø laser point
at distances

6 / 30 / 40 mm
(10 / 50 / 60 m)

General

Laser class

2

Laser type

635 nm, < 1 mW

Protection class

IP54 (dust- and splash
water protected)

Autom. laser switch off

after 90 s

Autom. power switch-off

after 180 s

Battery durability (2 x AAA)

up to 5000 measure-
ments

Dimension (H x D x W)

117 x 57 x 32 mm
4.6 x 2.4 x 1.3 in

Weight (with batteries)

0.14 kg / 4.938 oz

Temperature range:
- Storage

- Operation

-25 to 70 °C
-13 to 158 °F
-10 to 50 °C
14 to 122 °F

Functions

Distance measuring

yes

Min/Max measuring

yes

Permanent measuring

yes

Stake-out

yes

Addition/Subtraction

yes

Area

yes

Volume

yes

Pythagoras

2-point, 3-point

Memory

10 displays

Beep

yes

Illuminated display

yes

Multifunctional endpiece

yes

No.

Cause

Correction

204

Calculation error

Perform measurement
again.

252

Temperature too
high

Let device cool down.

253

Temperature too
low

Warm device up.

255

Received signal too
weak, measuring
time too long

Change target surface
(e.g. white paper).

256

Received signal too
high

Change target surface
(e.g. white paper).

257

Too much back-
ground light

Shadow target area.

258

Measurement
outside of meas-
uring range

Correct range.

260

Laser beam inter-
rupted

Repeat measurement.