Wiring: 9-pin connector cont – Crimestopper Security Products SP-400 User Manual
Page 5
5
WIRING: 9-PIN Connector Cont.
Green/Red: (-) 500mA Remote Aux. Output 1 (Programmable Option #10, requires relay)
This is a programmable output that can operate two different ways: 1 - (DEFAULT) Disarm with Remote Auxiliary
Output that provides a ½ second (-) Negative pulse when Button #3 is pressed to open a Factory power trunk or
hatch release. 2 - Remote Auxiliary Output without disarm
GREEN/RED
85
86
30
87
Trunk Soleniod
Dome Light
NEGATIVE AUXILARY OUTPUT
OR *
+12V CONSTANT
+12V CONSTANT
-OR-
Aux Function
* Test activation circuit in vehicle.
Connect to+12V for Positive circuits
or Ground for Negative circuits. Relay
not included.
(-) AUX OUTPUT
OR
-OR-
Blue/Black: (-) 500mA IGNITION OUT or REMOTE AUX. Output #2 (Programmable Option #17)
This wire functions as a Negative IGNITION OUTPUT (Ground while Remote Starting) for use when connecting
factory Security Bypass modules or when an additional external Ignition Relay is required for your installation. This
wire can be programmed to function as an AUXILIARY OUTPUT #2 providing a momentary (-) Negative output
when Button #6 then #1 is pressed and held for more than 2 seconds. The Aux Channel #2 output stays on as long
a the button is held down. Connect to the Negative activation circuit of an auxiliary module or device.