LAARS Mini-Combo id MCH - Install and Operating Manual User Manual
Page 3
Mini-Combo id
Page 3
SECTION 1.
General Information
WARNING
This manual supplies information on the application,
installation and operation of the indirect water
heater unit. A complete instruction manual of the
operation of the hydronic boiler (Document 1080) is
supplied along with this manual. Both manuals
should be reviewed completely before proceeding
with the installation.
•
Failure to follow the instructions provided may
result in personal injury, death or substantial
property damage.
•
Any modifications to the boiler, water tank, gas
and water connections, or wiring may void
warranty.
•
Consult the factory or local factory
representative with any questions or problems
regarding this equipment.
Hazards and Your Safety — Hot Water
Can Scald!
Consumer Product Safety Commission and some
states/provinces recommend a temperature setting of
130°F (54°C) or less. The water heater thermostat is
factory set to approximately 120°F (49°C). If
thermostat will be set above factory setting, install an
anti-scald valve at either the water heater or at each
hot water faucet.
• Tempering valves are not anti-scald valves since
they do not have a positive shutoff in case cold
water supply fails. They are not recommended
for shower/tub service. If needed, install an anti-
scald valve at each shower/tub.
• Water heated to a temperature suitable for
clothes washing, dish washing and other
sanitizing needs can scald and cause permanent
injury.
• Children and elderly, infirm, or physically
handicapped persons are more likely to be
injured by hot water. Never leave them
unattended in a bathtub or shower. Never allow
small children to use a hot water tap or draw
their own bath. If anyone using hot water in the
building fits this description, or if state/province
laws or local codes require certain water
temperature at hot water taps, take special
precautions:
Install an anti-scald valve at water heater or at
each hot water faucet, bath, and shower outlet.
Use lowest practical temperature setting.
• Studies have indicated that dangerous bacteria
can form in potable water distribution system if
certain minimum water temperatures are not
maintained. Contact local health department for
more information.
SECTION 2.
Installation
This installation must conform with the
instructions in this manual and, where applicable:
• Local, state, provincial, and national codes, laws,
regulations and ordinances.
• In Canada — CAN/CGA B149.1 or B149.2
installation Code.
Where the recommendations made in this manual
differ from local or national codes, the local or
national codes take precedence.
2A. Location
This water heater/boiler unit is not intended for
outdoor installation. Select a convenient location
where water leakage from the tank or connections will
not result in damage to areas adjacent to the appliance
or to lower floors of the structure. When a safe
location cannot be found, install a suitable drain pan
under the appliance, and pipe it to an adequate drain.
Figure 1. Closet Installation.
Top Clearance
29
(737)
2
(51)
2
(51)
25.25
(641)
23 (584)
4 (102)
2 (51)
Dimensions
shown in inches
(mm).
57.75
(1467)
63.5
(1613)