LAARS Rheos Vent Terminal - Service Manual User Manual
Rheos vent terminal, For outdoor units only), Vent termination, flue outlet general description
Rheos Vent Terminal
(for outdoor units only)
IMPORTANT: Read and comply with all warnings and instructions listed in
the “Installation and Operation Instructions” included with the unit.
800.900.9276 • Fax 800.559.1583
(Customer Service, Service Advisors)
20 Industrial Way, Rochester, NH 03867 • 603.335.6300 • Fax 603.335.3355
(Applications Engineering)
1869 Sismet Road, Mississauga, Ontario, Canada L4W 1W8 • 905.238.0100 • Fax 905.366.0130
www.Laars.com
Litho in U.S.A. © Laars Heating Systems 0911 Doc. 4228
Engineering Data
Document 4228
Vent Termination, Flue Outlet
General Description
Single wall mitered termination with screen used
on horizontal or vertical gas vent systems.
Material
AL-29-4C
®
Alloy Stainless Steel
Figure 1. Vent Termination, Flue Outlet.
Figure 2. Appliance Adapter, Flue Collar.
Appliance Adapter, Flue Collar
General Description
Single wall generic flue adapter with split seam.
Hose clamps tighten around outside to create a
mechanical seal.
Material
AL-29-4C
®
Alloy Stainless Steel
VENT
APPLIANCE
A
B
C
D
TERMINATION
ADAPTER
SIZE
PART NUMBER
PART NUMBER
in
cm
in
cm
in
cm
in
cm
1200
D2008300
D2008500
8.5
22
6.0
15
6.0
15
5.75
15
1600
D2008300
D2008500
8.5
22
6.0
15
6.0
15
5.75
15
2000
D2008400
D2008600
10.25 26
7.0
18
7.0
18
6.75
17
2400
D2007500
D2008600
13.25 34
10.0
25
10.0
25
9.75
25
Laars Heating Systems Company reserves the right to change specifications, components, features, or to discontinue products without notice.