beautypg.com

LAARS IGE-199C - Installation Manual User Manual

Page 5

background image

SECTION II: SPECIFICATIONS


Max. Flow Rate @ Degree Temperature Rise

Max.

Input

Rating

Btu/hr.

Min.

Input

Rating

Btu/hr.


Temp Rise


40

°F


60

°F


80

°F


100

°F


120

°F



Model No.

140

°F

5

Flow Rate vs Temperature Rise Curve for EVERHOT

® IGE model series

0

1

2

3

4

5

6

7

8

9

0

25

50

75

100

125

150

ΔT – Temperature Rise (°F)

Max. Flow (gpm)*

*Note: The maximum flow is based upon a minimum water pressure of 30 PSI

Flow Rate

Gal/Min.

7.3 5.9 4.2 3.3 2.8 2.4

IGE-199R-10N
IGE-199R-10X
IGE-199C-5N

199,000

15,000

First Hour

Supply
Gal/Hr

.

438 354 252 198 168

IGE-199C-5X

144

Max. Flow Rate @ Degree Temperature Rise


Model No.

Max.

Input

Rating

kW/hr.

Min.

Input

Rating
kW/hr.


Temp Rise


22

°C


33

°C


44

°C


56

°C


67

°C


78

°C

Flow Rate

Liters/

Min.

27.6 22.3 15.9 12.5 10.6 9.1

IGE-199R-10N
IGE-199R-10X
IGE-199C-5N
IGE-199C-5X

58.3

4.4

First Hour

Supply

Liters/Hr

.

1656

1338

954 750 636 545

This manual is related to the following products: