Iii - program codes, Declaration of programs, subroutines and plcs, Iii – program codes – Conair S900II User Manual
Page 23
System Configuration
S900II
III – Program codes
21
01T01350_0
2.2.98
III – PROGRAM CODES
III – 1. Declaration of programs, subroutines and PLCs
"
Header codes of PRG, SP,..., SR, PLC
G F9b xn
= Main program
G b = 0, standard PRG (encoded on 15 bits)
b = 1 , SAP PRG (encoded on 15 bits)
G FAnn
= STD, STK.. // subroutine (see stacking header)
G FBnn
= Return subroutine (see home return header)
G FCnn
= PLC program
G FEnn
= FREE
"
STEP TRANSITION codes
G EC00 + Step number 0 to 999
G E.g. : EC12 => Step number 18 (decimal)
G E.g. : ED00 => Step number 256 (decimal)
"
END of PRG, SP..., SR, PLC codes
G F0nn
= End of ”standard” SP nn.
G F1nn
= End of ”standard” stacking SP nn.
G F2nn
= End of ”general” stacking SP nn.
G F3nn
= End of SP // nn.
G F4nn
= End of simple or total SR nn.
G F8nn
= End of simple or total SR with return to step 0 of PRG 00.
G F5nn
= End of PLC nn.
G F7nn
= End of main program (PRG) nn.
"
PRG architecture in the memory area
previous program
F9 nn
F7 nn
PRG (text)
FA xx
F1 xx
SP
FB pp
F4 pp
SR
F9 mm
PRG nn
following PRG