System Configuration
S900II
II – Instruction codes
20
01T01350_0
2.2.98
II – 2. PLC programs
Type
of Instruction
Display
Codop (hexadecimal)
PROG.PLC xx header (num)
PLC xx
FC [oper. 16 bits]
TEST CONDITION
IF ...
See part programs
INITIALISATION
SET ...
See part programs
RST ...
INC ...
DEC ...
COMPARISON xxxx > = xxxx
CMP 0000 (to 0015) VAL 0000 (to FFFF)
D020 [oper. 16 bits] [oper. 16 bits]
0000 (to 0015)
TIMER xx VALUE xxxx
TIMER 00 (to 15) VAL 0000 (to 9999)
D021 [oper. 16 bits] [oper. 16 bits]
AND FUNCTION on BIT
AND BIT 000 (to 127)
D022 [oper. 16 bits]
AND FUNCTION on OUTPUT
AND OUT 000 (to 127)
D023 [oper. 16 bits]
AND FUNCTION on BIT
OR BIT 000 (to 127)
D024 [oper. 16 bits]
OR FUNCTION on OUTPUT
OR OUT 000 (to 127)
D025 [oper. 16 bits]
END OF PROGRAM
END
F5 [oper. 16 bits]
PLC No.
Counter No.
Value
Timer No.
Pre–selection No.
Variables No.
PLC No.