Craftsman 919.15216 User Manual
Page 19
19 - ENG
PrOBLeM
CAUSE
COrreCTiON
Regulator will not shut
off air outlet.
Damaged regulator.
Replace.
Motor will not run.
Fuse blown, circuit
breaker tripped.
Check fuse box
for blown fuse and
replace as necessary.
Reset circuit breaker.
Do not use a fuse or
circuit breaker with
higher rating than
that specified for your
particular branch circuit.
Check for proper fuse.
You should use a time
delay fuse.
Check for low voltage
problem.
Check the extension
cord.
Disconnect the other
electrical appliances
from circuit or operate
the compressor on its
own branch circuit.
Extension cord is wrong
length or gauge.
Check the extension
cord.
Loose electrical
connections.
Check wiring
connection inside
terminal box.
Faulty motor.
Have checked by
a Trained Service
Technician.
Motor overload protec-
tion switch has tripped
Refer to
Motor
Overload Protection
under Operation.
If motor overload
protection trips
frequently, contact
a Trained Service
Technician.