WIRING

PIN 5: GREEN: (-) START ACTIVATION INPUT, OEM
INTERFACE or TURBO TIMER INPUT

Momentary

Switch

New TURBO TIMER MODE

GREEN

EZ-30 EXPANSION (Default)

EZ-30 OEM INTERFACE

GREEN

GREEN

(Not included)

(Aux Channel

AFTERMARKET

1 sec. (-) pulse

FACTORY KEYLESS

Output)

ALARM / KEYLESS

MODULE

3 Consecutive

(-) pulses


See descriptions & diagrams below.

Mode (1) [Default (-) Neg. Start Activation] This wire
allows a host (or parent) alarm’s or keyless entry system
to activate a Remote Start by sending a 1-Second
Negative signal to the Green input wire to trigger a
remote engine start or stop. Connect the Green wire to
the host system’s Auxiliary channel output wire.

Mode (2) [Alternate OEM Interface] This mode allows
the system to Remote Start or Stop when 3 successive
Negative pulses are sent to the Green input wire.
Connect the Green input wire to the Negative lock signal
wire of the factory system. If your Factory OEM system
does not have this type of signal, then a relay is
required.

TURBO TIMER INPUT [No programming required] This
wire allows the system to keep a vehicle running for 1-5
minutes [selectively] after removing the key. This mode
requires the use of a momentary switch that is not
included with the kit. Connect a 2-pole momentary
switch with one side to chassis Ground and the other
side to the Green input wire. If you own a turbo or turbo
diesel vehicle, you can now allow the EZEE Start
system to keep your engine running for 1-5 minutes after
exiting/locking your vehicle to cool-down without the need for an external “Turbo Timer”.

NOTE: The turbo timer button will also trigger a remote start if it is inadvertently pressed when the
vehicle is not running. Please note this when installing the button and choose a location out of harm’s
way

.