beautypg.com

Coleman Echelon FC9V User Manual

Page 3

background image

246786-CTG-B-0407

Unitary Products Group

3

AIR FLOW DATA

HIGH / LOW SPEED COOLING AND HEAT PUMP CFM - WITHOUT FILTERS

FC9V060B12DH11

FC9V080B12DH11

Jumper Settings

High

Low

High

Low

COOL Tap

ADJ Tap

1329

898

1312

878

A

B

1133

774

1117

741

B

B

1226

842

1202

810

A

A

1039

708

996

683

B

A

1110

755

1084

725

A

C

915

637

892

618

C

B

930

646

898

619

B

C

719

529

700

511

D

B

856

603

827

580

C

A

657

526

642

500

D

A

762

566

746

532

C

C

612

523

596

500

D

C

FC9V080C16DH11

FC9V100C20DH11

Jumper Settings

High

Low

High

Low

COOL Tap

ADJ Tap*

1758

1183

2196

1498

A

B

1646

1106

1858

1167

B

B

1699

1140

2045

1363

A

A

1531

1033

1661

1054

B

A

1527

1047

1884

1201

A

C

1449

969

1597

1022

C

B

1368

930

1506

947

B

C

1213

832

1395

891

D

B

1309

897

1477

922

C

A

1116

762

1254

761

D

A

1170

808

1304

801

C

C

1031

703

1114

657

D

C

FC9V120D20DH11

Jumper Settings

High

Low

COOL Tap

ADJ Tap*

2342

1528

A

B

1904

1229

B

B

2140

1404

A

A

1700

1096

B

A

1918

1247

A

C

1643

1044

C

B

1522

967

B

C

1418

852

D

B

1494

945

C

A

1287

772

D

A

1337

802

C

C

1132

668

D

C

HIGH / LOW HEAT CFM - WITHOUT FILTERS

FC9V060B12DH11

FC9V080B12DH11

Jumper Settings

High

Low

High

Low

HEAT Tap

ADJ Tap*

1137

720

1386

962

A

Any

974

625

1322

892

B

Any

883

593

1250

849

C

Any

825

561

1159

768

D

Any

FC9V080C16DH11

FC9V100C20DH11

Jumper Settings

High

Low

High

Low

HEAT Tap

ADJ Tap*

1732

1173

1912

1237

A

Any

1631

1110

1688

1079

B

Any

1493

1008

1545

967

C

Any

1359

931

1422

899

D

Any

FC9V120D20DH11

Jumper Settings

High

Low

HEAT Tap

ADJ Tap*

2238

1465

A

Any

2014

1313

B

Any

1863

1211

C

Any

1686

1075

D

Any

All CFM’s are shown at 0.5” w.c. external static pressure.These units have variable speed motors that automatically adjust to provide constant CFM from 0.0” to
0.6” w.c. static pressure. From 0.6” to 1.0” static pressure, CFM is reduced by 2% per 0.1” increase in static. Operation on duct systems with greater than 1.0”
w.c. external static pressure is not recommended.
NOTE: At some settings, LOW COOL and/or LOW HEAT airflow may be lower that what is required to operate an airflow switch on certain models of electronic
air cleaners. Consult the instructions for the electronic air cleaner for further details.
* The ADJ “D” tap should not be used.