Coleman Echelon FC9V User Manual
Page 2

246786-CTG-B-0407
2
Unitary Products Group
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
* Wire size and overcurrent protection must comply with the National Electric Code.
NOTES:
1. For altitudes above 2000 ft. reduce capacity 4% for each 1000 ft. above sea level.
2. Wire size based on copper conductors, 60°C, 3% voltage drop.
3. Continuous return air temperature must not be below 55°F.
4. All filters must be high velocity cleanable type.
C
19-1/4
1-1/4
1-1/4
5/8
5/8
23-5/8
D
2-1/4
23-1/4
20
B
BOTTOM IMAGE
SUPPLY END
TOP IMAGE
RETURN END
LEFT SIDE
RIGHT SIDE
22-3/4
7/8
7/8
13-7/8
HORIZONTAL CONDENSATE
DRAIN OPENING 2”
JUNCTION BOX
HOLE 7/8”
GAS PIPE ENTRY 1-1/2”
CONDENSATE DRAIN
HOLE 7/8”
SIDE PIPING HOLE 3-3/8”
T-STAT WIRING 7/8” K.O.
HORIZONTAL CONDENSATE
DRAIN OPENING 1-3/4”
22-1/4
25-3/8
26-1/2
27-1/8
29
22-3/4
21-5/8
18-1/2
11-3/4
7-1/2
2-1/4
T-STAT WIRING 7/8” K.O.
HORIZONTAL CONDENSATE
DRAIN OPENING 1-3/4”
HORIZONTAL
CONDENSATE
DRAIN OPENING 1-3/4”
JUNCTION BOX
HOLE 7/8”
GAS PIPE
ENTRY 1-1/2”
CONDENSATE DRAIN
HOLE 7/8”
29
22-3/4
21-1/4
18-1/2
9-1/8
8-1/2
30-1/8
23-11/16
E
FRONT
A
40
DIMENSIONS
Models
Nominal
CFM
Cabinet
Size
Cabinet Dimension
A (in.)
B (in.)
C (in.)
D (in.)
E (IN.)
FC9V060B12DH11
1200
B
17-1/2
16-1/4
15
1-3/4
2-3/8
FC9V080B12DH11
1200
B
17-1/2
16-1/4
15
1-3/4
2-3/8
FC9V080C16DH11
1600
C
21
19-3/4
18-1/2
2-1/8
2-3/4
FC9V100C20DH11
2000
C
21
19-3/4
18-1/2
2-1/8
2-3/4
FC9V120D20DH11
2000
D
24-1/2
23-1/4
22
2-1/2
3
ELECTRICAL AND PERFORMANCE DATA
Models
Input
(High/Low)
Output
(High/Low)
Nominal
Airflow
Cabinet
Width
Total Unit
AFUE
Air Temp.
Rise
MBH
MBH
CFM
In.
Amps
%
°F
FC9V060B12DH11
60 / 39
56 / 36
1200
17-1/2
9
92
35 - 65
FC9V080B12DH11
80 / 52
75 / 49
1200
17-1/2
9
92
35 - 65
FC9V080C16DH11
80 / 52
75 / 49
1600
21
12
92
35 - 65
FC9V100C20DH11
100 / 65
93 / 61
2000
21
14
92
35 - 65
FC9V120D20DH11
120 / 78
112 / 74
2000
24-1/2
14
92
35 - 65
Models
Input
(High/Low)
Max. Outlet
Air Temp.
Blower
Blower
Size
Max.
Over-current
Protect
Min. Wire Size *
(awg) @ 75 ft.
One Way
Operating
Weight
MBH
°F
HP
Amps
In.
Lbs.
FC9V060B12DH11
60 / 39
165
1/2
7.0
11 x 8
20
14
136
FC9V080B12DH11
80 / 52
165
1/2
7.0
11 x 8
20
14
143
FC9V080C16DH11
80 / 52
165
3/4
10.2
11 x 10
20
14
159
FC9V100C20DH11
100 / 65
165
1
12.7
11 x 11
20
12
164
FC9V120D20DH11
120 / 78
165
1
12.7
11 x 11
20
12
182