INSTALLATION INSTRUCTIONS

READ ALL

INSTRUCTIONS

AND SAFETY

INFORMATION.

CAUTION - High

Temperature, Keep

Electrical Cords,

Drapes, And Other

Furnishings Away

From Heater

WARNING!

RISK OF ELECTRICAL

SHOCK. TURN OFF

ALL POWER AT THE

ELECTRICAL PANEL

BOARD SUPPLYING

POWER TO THE

HEATER BEFORE

DOING ANY

ELECTRICAL WIRING.

WARNING!

Risk of Fire.

Heater must be

kept clear of all

obstructions:

12” in front and above;

6” on both sides

minimum.

IMPORTANT!

It is extremely

important that you

verify the electrical

supply wires are the

same voltage

as the heater (i.e. 120

volt heater to 120 volt

power supply and

240 volt heater to

240 volt power

supply). If replacing

an existing heater,

check the labels of

the old heater and

replace using the

same voltage.

Hooking a 240 volt

heater to a 120 volt

power supply will

drastically reduce

the heater’s output.

Hooking a 120 volt

heater to a 240 volt

power supply will

destroy the heater.

8. After confirming heater is level, fasten other end of

heater to wall stud with screw to wall.

SUPPLY

STUDS

FLOOR

FINISHED

WALL

Figure 1

STEP 1: Mount Heater to Wall

1. Locate wall studs closest to supply wires and position

heater (See Figure 1). NOTE: Wire connection is from
left side only on standard models.

STEP 2: Wiring Provisions / Wiring

This heating unit is designed for permanent installation.
All wiring should be routed in compliance with the
National Electrical Code and all local codes, where
applicable. A maximum of No. 10 AWG wire may be
used with this heater. All wiring should be planned
and run before heating units are set in place.
Standard units are wired from left end of the heater
only. (See Figure 5 for internal heater wiring).

When wiring unit through rear, remove knock out and
place heater on wall. Mark knockout location on wall.
When running conduit or cable to unit through flooring
and knock out in bottom of wiring compartment,
measure 1-1/2” (38mm) from wall and 2” (51mm)
from left end of unit. Cut a 7/8” (22mm) hole in floor
centered on the measured location (See Figure 6).

Connect the grounding lead to the green ground
screw (provided), using a connector. (See Figure 5).

Protect electrical supply from kinks, sharp objects, oil,
grease, hot surfaces or chemicals.

*Distance measured from finished floor surface.

2. Carefully remove front cover from heater by lifting

cover up from the bottom, and then outwards.
Set aside.

3. Remove wiring compartment cover, held by one

screw, from side you wish to wire. (Figure 2).

4. Remove slotted knockout closest to the supply

wires and install a strain relief connector.

5. Pull supply wires through the connector and secure,

leaving 6 inch wire leads for later use.

6. NOTE: If you will be installing a heater mounted

EBKN thermostat, you should do so now before
mounting your baseboard to the wall. See your
EBKN thermostat Owner’s Guide for instructions.

7. Position the heater and fasten one end of heater

to wall stud with screw in safe drill area as shown
in Figure 3. Before fastening to wall stud at other
end, place level across top of heater and make sure
heater is level. (Figure 4).

Figure 5

Figure 6

Figure 4

Checking with level

Figure 2

Left-end wiring shown

Figure 3

Drill areas
Left-end wiring shown

Left-end wiring (standard)

Ground

Screw

3