background image

(57) MODEL 603 FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 08/06/2012

57

SAVE THESE INSTRUCTIONS

Page 6

English

SETUP

INSTRUCTIONS

SETUP INSTRUCTIONS

Be sure you have access to water to fill the pool and chemicals for the water.
IMPORTANT: This filter pump is shipped with the air release valve (1) open

(open the air release valve if necessary). DO NOT replace the air release valve

until you reach STEP #8. Failure to follow these instructions will result in air

trapped inside filter housing; the motor will run dry, be noisy and
malfunction.
1.
Assemble above-ground-pool first. Carefully follow the pool’s installation

instructions.

2. Place the filter pump the length of the hose away from the pool wall where the

lower black protruding hose connection is "sticking-out".

3. Insert the nozzle union (9 & 10) into the upper protruding hose connections.

Then insert the strainer union

(9 & 11) into the lower protruding hose

connections. The hoses

(8) fit over the strainers inserted into the connections.

4. There are two hoses to be connected to the filter pump hose connections.

With hose clamps

(7), fasten one of the hoses (8) to the lower protruding hose

connection (marked "+" on the pool liner) and to the upper pump connection

(marked "+").

5. Connect the second hose to the remaining upper protruding hose connection

and to the lower pump connection. Make sure all the hose clamps

(7) are tight.

6. Twist the filter pump’s threaded cover (3) in a clock-wise direction to be sure

it is on "tight". Use only your hands to tighten the top. Do not tighten with tools

such as pliers.

7. Fill the pool to a level of at least 1-2 inches above the top connection. The

water will automatically flow down into the pump.

8. When water starts flowing out of the air release valve hole, screw in the air

release valve back into the filter housing cover. Do not over tighten the valve.

NOTE: Venting the system is necessary for air to escape as the filter

housing fills with water.

9. Connect the filter pump to the power outlet. The filter pump is now filtering the

water.

10. Operate the filter pump until the desired water clarity is obtained.

Risk of electric shock. Connect this product only to a grounding type

receptacle protected by a ground-fault circuit interrupter (GFCI). Contact a

qualified electrician if you cannot verify that the receptacle is protected by

a GFCI.

WARNING