Your monitor is designed to meet strict EPA (Environmental Protection Agency) Energy Star
requirements for reduced power consumption and to comply with the VESA Standard Display Power
Management Signal. Using a combination of hardware and software functions, this energy-saving
feature allows your computer to control your monitor’s power consumption and reduce your monitor’s
power state when not in use.
NOTE: Power consumption does not include the speaker power.
IMPORTANT: Your monitor’s energy saver feature works only when your monitor is connected to a computer
that also has energy saver features.
The following table describes your monitor energy saver levels in each of four power states:
Power Management States
State
LED color
Power
Consumption
Description
ON
Green
<100 watts
Normal operation
STANDBY/
SUSPEND
Yellow
<15 watts
Monitor screen is blank. High voltage is off. Heater
voltage is reduced. Full power mode returns quickly
(approximately 4 seconds).
SLEEP
Amber
<5 watts
Monitor screen is blank. High voltage is off. Heater
voltage is off. There is a brief warm-up period before
returning to full power mode (approximately 15
seconds).
The energy saver utility, with its energy saver features, is available with the Microsoft® Windows®
operating system, and some features are available in DOS. Refer to your computer’s user guide for
instructions on setting energy saver features (also referred to as power management features).