INSTALLATION
POWER SUPPLY SETTING
IMPORTANT!- FITTING A MAINS PLUG (U.K. only)
• Check that the type plate on the rear of your player
indicates the correct supply voltage.
• If your mams supply voltage is different, consult
your dealer or our Service Organisation.
Certain versions of this player are equipped with a
voltage selector (3), which enables you to set the
player to the correct mams voltage yourself. When
changing the voltage setting, it is also necessary to
change the mams fuse to one of the correct rating;
200 mA (slow blow fuse) for 110/127 V and 100 mA
(slow blow fuse) for 220/240 V.
CONNECTIONS (Fig. 1)
1 Mains fuse holder (not all versions)
See 'Power supply setting’.
2 Mains socket
• Insert the plug of the mams lead (supplied) into the
mams socket.
• Connect the other end to your mams supply.
- The mains supply is now switched on.
3 Voltage selector (not all versions)
See 'Power supply setting'.
4 ANALOGUE OUTPUT
For the connecting cable to the amplifier.
• Insert a red plug into the 'R' socket and the other
plug into the 'L' socket.
• Insert the two other plugs into the corresponding
sockets of the CD or AUX input of your amplifier.
You can also use the TUNER or TAPE IN connec
tion, but never the PHONO input!
5 REMOTE IN/OUT (CD 500 only)
Use this connection for:
-
connecting up the equipment when you are
incorporating the player in a PHILIPS HiR system
with Its own remote control system.
- connecting the remote control receiver EM 2200,
available as an accessory.
(Not available in the U.K.)
The wires in the mains lead are coloured in ac
cordance with the following code: Blue - Neutral;
Brown - Live. As the colours of the wires may not
correspond with the terminal identification in your
plug, proceed as follows:
• Connect the brown wire to the terminal marked 'L'
or coloured brown or red.
• Connect the blue wire to the terminal marked 'N' or
coloured blue or black.
No connection should be made to the earth terminal
of the plug!
For 13 A plugs, conforming to BS1363, use a 3 A
fuse. For other plugs, use a 5 A or lower fuse m the