beautypg.com

Getting started, Warning, Caution – Vermont Casting MO18 User Manual

Page 5

background image

20012914 7/05 Rev. 0

5

2

Getting Started

A. Size of Firebox

See Table 1 in Section 1.B.

Asphyxiation Risk
This appliance produces carbon monoxide

(CO).

• The free opening areas (in square inches)

of the chimney damper as shown in the

tables must be met.

• User must make sure damper is locked

open.

• The installer is responsible to ensure

proper ventilation of flue gases before

appliance is used.

Fire needs to draft properly for safe

operation.

WARNING

B. Negative Pressure

Negative pressure results from the imbalance of air avail-

able for the fireplace to operate properly. Causes for this

imbalance include:

• Exhaust fans (kitchen, bath, etc.).

• Range hoods.

• Combustion air requirements for furnaces, water heaters

and other combustion appliances.

• Clothes dryers.

• Location of return-air vents to furnace or air

conditioning.

• Imbalances of the HVAC air handling system.

• Upper level air leaks: recessed lighting, attic hatch

opening, duct leaks.

C. Tools and Supplies Needed

Tools and supplies normally required for installation:

Pliers
Phillips screwdriver
Tape measure
Crescent wrenches
Gas shutoff valve
Non-corrosive leak check solution
/4 in. wrench, 7/16 in. wrench

Sharp Edges

• Wear protective gloves

and safety glasses during

installation.

CAUTION

D. Inspect the Appliance and Components

• Remove the contents from the carton. Attached to the

burner are tags identifying the manufacturer name, serial

number, model number (including gas log size), BTU

ratings, gas type, etc.

• Review the attached tags before proceeding. Ensure

that all minimum fireplace dimension requirements are

achieved using Table 1 in Section 1.B. Ensure the gas

type provided in the fireplace coincide with the gas type

marked on the tag.

CFM disclaims any responsibility for, and

the warranty will be voided by, the following

actions:

• Installation and use of any damaged appliance or

vent system component.

• Modification of the appliance or vent system.

• Installation other than as instructed by CFM•

Improper positioning of the gas logs or the glass

door.

• Installation and/or use of any component part not

approved by CFM.

Any such action may cause a fire hazard.

WARNING

Rear dimension

Depth dimension

Front dimension