beautypg.com

Canon IP ReadyTM Series Video Alarm FDP75C12N User Manual

Page 20

background image

- 0 -

WIRING INSTRUCTIONS

Wiring Color Code Power and Control Inputs

RJ45

BNC

(Large)

Power

(Small)
Alarms

AFTER CAMERA INSTALLATION

Make inside housing wiring connections following Chart B
below.

Chart A Wiring Color Code

Power and Control Inputs (Outside of housing)

POWER

1

Camera Power (+12 VDC)

Red

2

Camera Power (-12 VDC)

Orange

3

Accessory Power (+12 VDC)

Yellow

4

Accessory Power (-12 VDC)

Green

CONTROL

RJ45 Ethernet Connector

ALARMS

1

Alarm 1

Blue

2

Alarm 2

Violet

3

Alarm 3

Gray

4

Common

White

Chart B Power and Control Outputs

(Inside of housing)

POWER

1

Camera Power (+12 VDC)

Red

2

Camera Power (-12 VDC)

Orange

ALARMS

1

Alarm 1

Blue

2

Alarm 2

Violet

3

Alarm 3

Gray

4

Common

White

!

Be sure the bracket is properly and securely mounted
to a supporting structure capable of rigidly holding
the weight of the entire unit.

INSTALLING THE HOUSING ASSEMBLY:

NOTE: This unit is designed for operation in an

upright position. Installing the housing
upside down may cause damage to
the internal equipment, and will void the
warranty.

INSTALLING PENDANT MOUNT

1. This unit includes a 1½" NPT housing for a standard 1½"

NPT pipe. The housing can be used with other brackets
designed with 1½" male pipe threads, such as the WM20G
wall mount bracket.

2. Attach the housing coupling.

Add thread

sealing tape

NOTE: Pipe threads should be clean and rust-

free. Use the Teflon

tape included with

the housing on the threads.

Teflon Tape

A small roll of Teflon tape is provided with all pendant units.

This manual is related to the following products: