beautypg.com

Serial ports, Arming time – Interlogix TVE-DEC10 User Manual

Page 27

background image

TVE-DEC10 IP Video Decoder User Manual

23

2. Select an alarm output from the drop-down list.

3. Select a time out option from the

Output Delay

drop-down list.

The time out setting lets you define for how long a signal remains active after
the alarm has ended. Select a time out option: 5, 10, and 30 seconds, 1, 2, 5,
and 10 minutes, and Manual stop. If “Manual stop” is selected, the alarm
output will stop only when the alarm input is manually stopped.

4. Click

Save

to save settings

.

Serial ports

Use this men u to configure the settings of the RS-232 and RS-485 ports.

To set up a serial port:

1. Click

Configuration

>

Serial Port Parameters.

The Serial Port Parameters

window appears.

2. Select the required serial port from the drop-down list: RS-232 or RS-485.

3. Enter the values for the following parameters:

RS-232 selected: Duplex mode, baud rate, data bit, parity type, and
operation mode.

RS-485 selected: Duplex mode, baud rate, data bit, stop bit, and parity type.

4. Click

Save

to save settings

.

Arming time

You can set up to eight arming schedules for alarm inputs.

To set up the arming schedules:

1. Click

Configuration

>

Arming time.

The Arming Time window appears.