Chapter 11 digital outputs & pwm outputs – Haltech E6GMX User Manual
Page 77
E6GMX Manual
77
CHAPTER 11
DIGITAL OUTPUTS & PWM OUTPUTS
The digital outputs and PWM outputs can be programmed to operate a wide variety of
functions. Some of the functions have restrictions to their operation.
Below is a table showing the ECU’s configurable outputs and their factory information.
Output Information
ECU Output
Factory feature
Pin
Digital Out 1
TCC
A7
Digital Out 2
Thermo fan
C1
PWM Out 1
A/C Control
C2
PWM Out 2
4
th
Gear
C7
PWM Out 3
Spare
F2
PWM Out 4
Spare
F4
Auxiliary Out (Aux Out)
Bypass
D5
The functions and their restrictions are described in the table below:
Output Description
Digital Out 1–2
PWM 1 – 4
Max #
Turbo Wastegate
N/A
•
2
Bypass Air Control (BAC)
N/A
•
1
Dual Intake Valve
•
•
Unrestricted
Torque Converter Control
•
•
1
Thermofan
•
•
Unrestricted
Intercooler Fan
•
•
Unrestricted
Shift Light
•
•
Unrestricted
Aux Fuel Pump
•
•
Unrestricted
Stall Saver
•
•
1
Staging Signal
•
•
Unrestricted
Turbo Timer
•
•
1
NOS Switch
•
•
1
Anti-Lag Switch
•
•
1
BAC2
N/A
PWM 3 & 4
1
BAC2/BAC Slave
N/A
PWM 3 & 4
1
TPS Switch
•
•
Unrestricted
For installation information regarding any hardware associated with the described output
functions refer to CHAPTER 1 Haltech ECU Installation, p11.
Each individual function and its parameters are described below.