111
ECU Outputs
•
Injector Driver
4 x Two State Programmable Peak-and-hold current limiting drivers capable of driving at:
- 4Apk/1Ahold
- 8Apk/2Ahold
The above current specifications allow the drivers to drive up to 8 x 2.2~2.4
Ω
injectors, 16 x saturation
style injectors (High Impedance) or 4 x ~0.5
Ω
.
CAUTION: Ensure software settings are correct since excessive current for long periods may damage
injectors.
•
Ignition Output
0-12V square-wave output used to drive an ignitor. Capable of driving ‘Smart’ and ‘Dumb’ ignitors.
CAUTION: This output cannot be used to drive coils directly an ignitor must be used to supply the high
coil currents
•
Pulse Width Modulated (PWM) Output
4 x PWM outputs capable of driving: 1A continuous pull to ground
-
Suitable for controlling turbo waste-gate, solenoids, valves, shift lights, relays etc.
-
Factory outputs can be configured to allow further features.
•
Special Purpose Digital Output
Up to 2 special purpose digital outputs capable of driving: 1A continuous pull to ground or low current
0-12V voltage level signal.
(actual number available dependant on Injection and Ignition configuration
-
12Volt logic outputs
-
Suitable for switching fans, shift lights, anti-lag, NOS, relaysetc.
•
Fuel Pump Control
System Programming Requirements
•
Computer
HalwinX requires a PC running Windows 95 release 2, Windows 98, Windows 2000, Windows
Millennium or Windows XP with the following specifications.
Minimum Requirements:
233MHz
processor
VGA colour display 800x600 (preferably 1024x768)
4 MB of memory
10 MB of free Disk space
Recommended:
PIII
500MHz processor
VGA colour display 1024x768
16 MB of memory
10 MB of free Disk space
•
Disk Drive
3.5" Floppy Disk Drive
•
Serial Port
Standard RS232C port - 9 pin D connector